Send Message

IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed

500 m
MOQ
On Request
Price
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed
Features Gallery Product Description Request A Quote
Features
Specifications
Rated Voltage: 0.6 / 1 KV
Conductor: Bear Copper
No. Of Cores: 4 Cores
Insulation: PVC
Armoured Type: Unarmoured
Sheath: PVC Compound
High Light:

pvc electrical cable

,

pvc copper cable

,

IEC 60502-1 pvc insulated armoured cable

Basic Infomation
Place of Origin: Shenzhen, Mainland China
Brand Name: Chengtiantai Cable
Certification: CE, CB
Model Number: VV22
Payment & Shipping Terms
Packaging Details: Steel Wooden Drum
Delivery Time: 15 working days after payments
Payment Terms: L/C, T/T
Supply Ability: 20 km / day
Product Description


0.6/1kV, PVC Insulated Cables according to IEC 60502-1 (armoured)


Application:


These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

 Construction:

 

1. Conductors:

------------------------------------------------------------------------------------------------------

–​ Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN 60228.

 

–​ For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.

 

2. Insulation

------------------------------------------------------------------------------------------------------

PVC Insulation material and thickness shall be as per IEC 60502-1 and BS 6346. PVC material shall be Type A as per IEC 60502-1 or TI1 as per BS EN 50363.


3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non armoured cables, this layer may be omitted


4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC 60502 or as per BS 5467, BS 6346. Single core cables shall be Aluminium wire armour. Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.


5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.

Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request.

 

6. Fire Performance of Cable Sheaths

------------------------------------------------------------------------------------------------------

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24,can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards.

 

 

  Physical and Electrical Characteristics:

 

4 CORE CABLE (ARMOURED)

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
4×4 1.0 1.8 18.2 529 30 37 4.61
4×6 1.0 1.8 19.3 641 38 46 3.08
4×10 1.0 1.8 22.5 905 53 64 1.83
4×16 1.0 1.8 25.0 1218 71 83 1.15
4×25 1.2 1.8 29.2 1690 94 108 0.73
4×35 1.2 1.9 33.5 2479 117 132 0.52
4×50 1.4 2.0 34.3 2963 140 157 0.39
4×70 1.4 2.2 37.8 3831 178 196 0.27
4×95 1.6 2.4 43.1 5032 219 234 0.19
4×120 1.6 2.5 46.3 6105 255 268 0.15
4×150 1.8 2.6 51.0 7475 294 301 0.12
4×185 2.0 2.8 56.2 9070 333 338 0.10
4×240 2.2 3.0 61.3 11664 397 393 0.08
4×300 2.4 3.2 69.3 15018 464 448 0.06

 

 

INSTALLATION METHOD DETAILS

 

IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 0   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 1   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 2   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 3
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 4   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 5   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 6   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 7
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 8   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 9   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 10   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 11
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 12   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 13   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 14   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 15
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 16   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 17   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 18   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 19
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 20   IEC 60502-1 Cable 4 Core PVC Insulated (armoured) Cu-conductor PVC insulated Steel Tape Armored PVC Sheathed 21        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

 

Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  RECOMMENDED ORDERING PARAMETERS

  CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

  WARRANTY

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

 
 
 
 
Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)