Send Message

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard

Negotiable
MOQ
On Request
Price
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard
Features Gallery Product Description Request A Quote
Features
Specifications
Rated Voltage: 0.6 / 1 KV
Conductor: BareCopper
No. Of Cores: 1 Cores
Insulation: PVC
Armoured Type: Unarmoured
Sheath: PVC Compound
High Light:

pvc electrical cable

,

pvc copper cable

,

pvc insulated and sheathed cable

Basic Infomation
Place of Origin: Shenzhen, Mainland China
Brand Name: Chengtiantai Cable
Certification: CE, CB
Model Number: VV
Payment & Shipping Terms
Packaging Details: Steel Wooden Drum
Delivery Time: 15 working days after payments
Payment Terms: L/C, T/T
Supply Ability: 20 km / day
Product Description

0.6/1kV, PVC Insulated Cables according to IEC 60502-1 (unarmoured)

 

 

Power cables for energy supply are installed in open air, in underground, indoors, in cable ducts, power stations, residental connections and street lighting as well as in subscriber networks, where mechanical damages are not be expected.

 

 

Quick details

-------------------------------------------------------

– Nominal cross section:1X120mm2

– Overall diameter Ø approx:21.1mm

– Net weight approx: 1384 kg/km

– Conductor DC resistant at 20°C:0.15Ω/km

Electrical characteristics

-------------------------------------------------------

–Rated voltage Uo/U (Um): 600 / 1000 V

–Maximum current rating air 30°C:325A

–Maximum current rating buried 20°C: 325A

–Maximum DC resistance, conductor 20°C:0.15Ω / km

–Test voltage: 4000 V

Dimensional characteristics

-------------------------------------------------------

– Nominal cross-section: 120mm2

– No of Conductors: single Core

– Insulation thickness: 1.6mm

– sheath thickness nominal value:1.5 mm

– Max overall diameter Ø: 21.1 mm

– Approximate weight:1384 kg/km

 

Usage characteristics

-------------------------------------------------------

– Maximum operating temperature: 90 °C

– Short circuit temperature: +250°C (short circuit duration max. 5 s)

– during installation up to -20°C

– Temperature range: - 20 to + 90 °C

– Minimum bending radius:15 x cable Ø

 

Standards

-------------------------------------------------------

International: IEC 60502-1
National:GB/ T 12706.1-2008

Construction characteristics

-------------------------------------------------------
1. Conductor
– Bare copper conductor, Class 2 to IEC 60228

–​ For smaller sizes, a solid round conductor, Class 1
2. Insulation: XLPE Compound

3. Filler: PP filler
4. Outer Sheath :PVC Compound
5. Sheath colour :Black

Note:

when required for a particular application, other colors are available.

RECOMMENDED ORDERING PARAMETERS

-------------------------------------------------------

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

Shenzhen chengtiantai cable

 

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 0

Cable production started 1983 with 35 years of cable manufacturing experience.Sales in 2016 about 500 million USD

Our production in numbers

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 1

200 Sets Of Testing Equipment, 100 Testing Items, 8 workshop

40 wire drawing machines,10 bunching machines, 28 Extruder system, 42 stranding machines,10 Braiding machines

Manufacturing Plant

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 2
100,000 m2 Production area

2 Manufacturing plant
1 R&D Center

350 Will-trained employees

Our products at a glance

 

–​ Medium voltage power cable 

–​ 0.6/1 kV Low volate power cable

–​ Copper building wire up to 750 Volts

–​ Ethernet Lan cable cat.5e, cat6, cat.6A cat.7

–​ Control cable

–​ Fibre optical cable

–​ Coxial cable

CONTACT US

 

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 3

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com

Head office:

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 4Chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

 

  Physical and Electrical Characteristics:

 

 

 

 

INSTALLATION METHOD DETAILS

 

1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 5   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 6   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 7   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 8
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 9   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 10   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 11   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 12
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 13   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 14   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 15   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 16
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 17   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 18   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 19   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 20
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 21   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 22   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 23   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 24
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 25   1*120 Sq Mm PVC Insulated Power Cable One Core IEC 60502-1 Standard 26        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

  WARRANTY

-----------------------------------------------------------------------------------------------------------

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

 

Note:

-----------------------------------------------------------------------------------------------------------

  • Photographs are not to scale and do not represent detailed images of the respective products
  • Sale to business customers only
  • Information in this document is subject to change without notice
Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)